Impact of structural variables on hydroenergetic efficientization of water pumping system

Authors

DOI:

https://doi.org/10.33448/rsd-v9i11.10553

Keywords:

Experimental planning; Energy efficiency; Water pumping system; Computational simulation.

Abstract

Evaluate the structural variables influence on the consumption and the electrical energy cost from Guamá river’s Water Pumping System (WPS) located in Belém city (Pará), through Plackett and Burman experimental planning, computational simulations and of statistical analysis. This present study was divided into four stages. In Step 1, it was carried out the design characterization and limits determination (minimum and maximum) of the variables geometric height, diameter and pressurized pipes length and stand pipe reservoir useful volume. Then (Step 2) it was applied the Plackett and Burman experimental planning, in order to define the number of tests to be simulated. In Step 3, it was held hydraulic simulations of different operational routines, to determine the consumption and electric power cost in the WPS. The last stage was accomplished statistical analysis (Hypothesis test and Pareto Diagram) for a 95% significance level. Based on the results, the structural variables that most impacted upon the consumption and the WPS electricity cost Guamá River were the useful volume daily required, followed by the pressurized pipe diameter. From the experimental planning technique application, the sanitation manager will be able to prioritize the energy efficiency actions of the investigated system.

References

Agência Nacional de Energia Elétrica. (2020). Tarifa branca. Recuperado de https://www.aneel.gov.br/tarifa-branca.

Azevedo Netto, J. M., Fernandez, M. F. (2015). Manual de Hidráulica (9a ed.) São Paulo: Edgard Blücher.

Brasil (2019). Ministério do Desenvolvimento Regional. Secretaria Nacional de Saneamento – SNS. Sistema Nacional de Informações sobre Saneamento - SNIS: 24º Diagnóstico dos Serviços de Água e Esgotos – 2018. Recuperado de http://www.snis.gov.br/downlo ads/diagnosticos/ae/2018/Diagnostico_AE2018.pdf.

Brandt, M., Middletom, R., Wheale, G. Schulting, F. (2011). Energy efficiency in the water industry, a Global Research Project. Water Practice and Technology. 6(2).

Colombo, A. F. & Karney, B. W. (2002). Energy and costs of leaky pipes: Toward comprehensive Picture. Journal of Water Resources Planning and Management, 128 (6), 441-450.

Custódio, L. M. & Lopes, R. E. (2018). Analise de viabilidade da utilização de bomba funcionando como turbina operando à frequência variável como alternativa de geração de energia comparado com eletrificação rural no estado de Minas Gerais. Research, society and development, 7 (6). 1-12.

Equatorial Energia (2018). Valor de tarifas e serviços. Recuperado de https://pa.equatorialenergia.com.br/informacoes-gerais/valor-de-tarifas-e-servicos/#demais-classes.

Galdamez, E. C. & Carpinetti, L R. (2004). Aplicação de técnicas de planejamento e análise de experimentos no processo de injeção plástica. Gestão e produção, 11 (1). 121-134.

Gomes, H. P. (2019). Abastecimento de Água. João Pessoa: LENHS/UFPB.

Gomes, H. P. (2012). Sistema de Bombeamento: Eficiência Energética. João Pessoa: Editora Universitária/UFPB.

Haaland, P. D. Experimental Desingn in Biotechnology. (1989). Nova York: Marcel Dekker.

Lima, A. C., Guimarães Júnioe, S. C., Fietz, C. R., Camacho, J. R. (2009). Avaliação e análise da eficiência energética na irrigação em sistemas de pivô central. Revista Brasileira de Engenharia Agrícola e Ambiental, 13 (4).

Montgomery, D. C., Runger, G. C., Hubele, N. F. (2004). Estatística Aplicada à Engenharia (2a ed.). Rio de Janeiro: LTC.

Moreira, F. N. C., Ferreira, J. F. H. e Pereira, J. A. R. (2020). Normas Brasileiras e a recomendação de eficiência energética para a elaboração do projeto de estação elevatória de esgoto sanitário. Research, society and development, 9 (8). 1-18.

Moreira, F. N. C., Rego, A. G., Pereira, J. A. R. (2019). Avaliação da Importância do Volume Útil de Reservatório Elevado para a Distribuição de Água para Área Urbana. Revista Aidis de Ingeniería y Ciencias Ambientales, 12 (3). 536-551.

Moreira, F. N. C. (2018). Dimensionamento do volume útil de reservação de água considerando o consumo de energia elétrica no horário de ponta do setor elétrico. Dissertação, Universidade Federal do Pará, Belém, Pará, Brasil.

Nascimento, D. L. G., Silva, A. B., Santos, A. C. P. A., Ferreira, J. F. H., Pereira, J. A. R. (2019). Impacto da Concepção no Consumo de Energia Elétrica do Sistema de Bombeamento e Adução de Água Bruta do Rio Guamá – Belém. XVI Seminário Ibero-Americano sobre Sistemas de Abastecimento e Drenagem - SEREA.

Paglarini, C. S., Furtado, G. F., Biachi, J. P., Vidal, V. A. S., Martini, S., Forte, M. B. S., Cunha, R. L., Pollonio, M. A. R. 2018. Functinal Emulsion Gels With Potential Application in Meat Products. Journal of Food Engineering, 222. 29-37.

Pereira, J. A. R. e Condurú, M. T. (2014). Abastecimento de água: informação para eficiência hidroenergética. João Pessoa – Brasil: Editora Universitária – UFPB.

Plackett, R. L. & Burman, J. P. (1946). The Desing of Optimum Multifactorial Experiments. Biometrika, 33 (4), 305-325.

Plano Diretor do Sistema de Abastecimento de Água da Região Metropolitana de Belém (2006). Universidade Federal do Pará. Grupo de Pesquisa Hidráulica e Saneamento (v. 2, p. 285).

Plano Municipal de Saneamento Básico (Água e Esgoto) (2014). Prefeitura Municipal de Belém. Recuperado de http://www.belem.pa.gov.br/arbel/wp-content/uploads/2014/09/PMSB-Bel%C3%A9m-PA_Volume-I2.pdf.

Qiang, X., et al (2015). Improving water and energy metabolism efficiency in urban water supply system through pressure stabilization by optimal operation on water tanks. Ecological Informatics. Journal homepage: www.elsevier.com/locate/ecol inf. 111-116.

Rodrigues, M. I. & Iemma, A. F. (2014). Planejamento de Experimentos e otimização de processos (3a ed.), Campinas, SP: Casa do Espirito Amigo Fraternidade Fé e Amor.

Santos, A. F., Luz, E., Freitas, S., Grell, G., Velho, H. de C., Gan, M. (2010). Analise de sensibilidade das simulações de precipitação convectiva do modelo brams as melhorias na parametrização de cumulus. In: XVI Congresso Brasileiro de Meteorologia.

Tarquim, A. J., Dowdy, J. (1989). Optimal Pump Operation in Water distribution. Journal of Hydraulic Engineering. New York, NY, USA: Asce, 115 (2), 158-168.

Ye Wanga; Puiga, V., Cebrano, G. (2017). Non-linear economic model predictive control of water distribution networks. Journal of Process Control. Journal home page: www.elsevier.com/locate/jprocont. 23–34.

Wenyan, W., et al (2012). Incorporation of Variable-Speed Pumping in Multiobjective Genetic Algorithm Optimization of the Design of Water Transmission Systems. Sociedade Americana de Engenheiros Civis. Journal of Water Resources Planning and Management. 543-552.

Wu, P., Lai, Z., Wu, D., Wang, L. (2014). Optimization research of parallel pump system for improving energy efficiency. Journal of Water Resources Planning and Management, 141 (8).

Published

08/12/2020

How to Cite

SILVA, A. B. da; PEREIRA, J. A. R. .; ALMEIDA, A. C. P. . Impact of structural variables on hydroenergetic efficientization of water pumping system. Research, Society and Development, [S. l.], v. 9, n. 11, p. e93591110553, 2020. DOI: 10.33448/rsd-v9i11.10553. Disponível em: https://www.rsdjournal.org/index.php/rsd/article/view/10553. Acesso em: 20 apr. 2024.

Issue

Section

Engineerings