Fatigue strength of Bassi LogicTM and Hyflex EDM endodontic instruments in an artificial canal with an extreme curvature

Authors

DOI:

https://doi.org/10.33448/rsd-v11i6.29570

Keywords:

Dental Instruments; Endodontics; Rotation.

Abstract

The objective of this study was to perform a comparative analysis of the fatigue strength of NiTi instruments in an in vitro model (artificial canal). Ten Hyflex EDM instruments (tip: 10; taper: .05) (Coltene/Whaledent, Altstätten, Switzerland) and ten Bassi LogicTM instruments (tip: 15; taper: .05) (Bassi Endo, Belo Horizonte, Brazil) were used. For the static bending fatigue strength test, we used a stainless-steel artificial canal with a 5-mm curvature radius, 90º curvature, and inner diameter of 1.5 mm. The instruments were run in the artificial canal until the occurrence of fracture. The time was recorded and the number of cycles was calculated. The length of the fragments was measured and three samples from each group were analyzed using scanning electron micrscopy for the characterization of metal fatigue. The data were compared using the nonparametric Man-Whitney test (samples with non-normal distribution), with the significance level set at 5% (p<0.05). Bassi LogicTM instruments tolerated a greater number of cycles compared to the Hyflex EDM (p < 0.05). Significant differences in fragment size were also found between groups (p < 0.05). Mean fragment size was larger among the Hyflex EDM instruments compared to the Bassi LogicTM instruments.The Bassi LogicTM 15.05 exhibited greater fatigue strength in artificial canals with an accentuated curvature compared to Hyflex EDM 10.05.

References

Alcalde, M. P, Duarte, M. A. H., Bramante, C. M., Tanomaru-Filho, M, Vasconcelos, B. C., Só, M. V. R., et al (2018). Torsional fatigue resistance of pathfinding instruments manufactured from several nickel-titanium alloys. Int Endod J, 51(6), 697-704.

Alcalde, M. P., Tanomaru-Filho, M, Bramante, C. M., Duarte, M. A. H., Guerreiro-Tanomaru, J. M., Camilo-Pinto, J., et al (2017). Cyclic and torsional fatigue resistance of reciprocating single files manufactured by different nickel-titanium Alloys. J Endod, 43(7), 1186-1191.

Basheer Ahamed, S. B., Vanajassun, P. P., Rajkumar, K., & Mahalaxmi, S. (2018). Comparative evaluation of stress distribution in experimentally designed nickel-titanium rotary files with varying cross sections: A finite element analysis. J Endod , 44(4), 654-658.

Bueno, C. R. E., Cury, M. T. S, Vasques, A. M. V., Sivieri-Araújo, G, Jacinto, R. C., Gomes-Filho, J. E. et al (2019). Cyclic fatigue resistance of novel genius and edgefile nickel-titanium reciprocating instruments. Braz Oral Res, 33, e028.

Capar, I. D., Ertas, H. & Arslan, H. (2015). Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments. Aust Endod J, 41(1), 24-28.

Cardoso, R. M., Carvalho Alves, N. C., de Menezes, S. E. A. C., Batista, S. M., Vieira, T. M., & Elgarten Rocha, G. N., et al (2019). Influence of temperature on the cyclic fatigue of nickel-titanium instruments with different heat treatments on severely curved canals. J Contemp Dent Pract, 20(6), 697-701.

Cheung, G. S., Peng, B., Bian, Z., Shen, Y., & Darvell, B. W. (2005). Defects in ProTaper S1 instruments after clinical use: fractographic examination. Int Endod J, 38(11), 802-809.

de Menezes, S. E. A. C., Batista, S. M., Lira, J. O. P., & de Melo Monteiro, G. Q. (2017). Cyclic fatigue resistance of WaveOne Gold, ProDesign R and ProDesign Logic files in curved canals in vitro. Iran Endod J, 12(4), 468-473.

Fernández-Pazos, G, Martín-Biedma, B, Varela-Patiño, P, Ruíz-Piñón, M, & Castelo-Baz, P (2018). Fracture and deformation of ProTaper Next instruments after clinical use. J Clin Exp Dent, 10(11), e1091-e1095.

Ferreira, F., Adeodato, C., Barbosa, I., Aboud, L., Scelza, P., & Zaccaro Scelza, M. (2017). Movement kinematics and cyclic fatigue of NiTi rotary instruments: a systematic review. Int Endod J, 50(2), 143-152.

Gambarini, G (2001). Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. Int Endod J, 34(5), 386-389.

Gao, Y, Shotton, V, Wilkinson, K, Phillips, G, & Johnson, W. B. (2010). Effects of raw material and rotational speed on the cyclic fatigue of ProFile Vortex rotary instruments. J Endod , 36(7), 1205-1209.

Gavini, G, Santos, M. D, Caldeira, C. L, Machado, M. E. L., Freire, L. G., Iglecias, E. F., et al (2018). Nickel-titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res, 32(suppl 1), e67.

Gündoğar, M, & Özyürek, T (2017). Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc Blue nickel-titanium instruments. J Endod, 43(7), 1192-1196.

İnan, U, & Keskin, C (2019). Torsional resistance of ProGlider, Hyflex EDM, and One G Glide Path instruments. J Endod, 45(10), 1253-1257.

Kaval, M. E, Capar, I. D, & Ertas, H (2016). Evaluation of the cyclic fatigue and torsional resistance of novel nickel-titanium rotary files with various alloy properties. J Endod, 42(12), 1840-1843.

Kosti, E, Zinelis, S, Molyvdas, I, & Lambrianidis, T (2011). Effect of root canal curvature on the failure incidence of ProFile rotary Ni-Ti endodontic instruments. Int Endod J, 44(10), 917-925.

Lopes, H. P, Ferreira, A. A, Elias, C. N, Moreira, E. J, de Oliveira, J. C, & Siqueira, J. F Jr (2009). Influence of rotational speed on the cyclic fatigue of rotary nickel-titanium endodontic instruments. J Endod, 35(7), 1013-6.

Lopes, H. P, Vieira, M. V, Elias, C. N, Gonçalves, L. S, Siqueira, J. F Jr, Moreira, E. J, et al (2013). Influence of the geometry of curved artificial canals on the fracture of rotary nickel-titanium instruments subjected to cyclic fatigue tests. J Endod, 39(5), 704-707.

Pedullà, E, Lo Savio, F, Boninelli, S, Plotino, G, Grande, N. M, La Rosa, G, et al (2016). Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod, 42(1), 156-159.

Pedullà, E, Plotino, G, Grande, N. M, Scibilia, M, Pappalardo, A, Malagnino, V. A, et al (2014). Influence of rotational speed on the cyclic fatigue of Mtwo instruments. Int Endod J, 47(6), 514-519.

Peters, O. A, de Azevedo Bahia, M G, & Pereira, E. S (2017). Contemporary root canal preparation: Innovations in biomechanics. Dent Clin North Am, 61(1), 37-58.

Pinheiro, S. R, Alcalde, M. P, Vivacqua-Gomes, N, Bramante, C. M, Vivan, R. R, Duarte, M. A. H, et al (2018). Evaluation of apical transportation and centring ability of five thermally treated NiTi rotary systems. Int Endod J, 51(6), 705-713.

Pirani, C, Iacono, F, Generali, L, Sassatelli, P, Nucci, C, Lusvarghi, L, et al (2016). HyFlex EDM: superficial features, metallurgical analysis and fatigue resistance of innovative electro discharge machined NiTi rotary instruments. Int Endod J, 49(5), 483-493.

Plotino, G, Grande, NM, Cordaro, M, Testarelli, L, & Gambarini, G (2009). A review of cyclic fatigue testing of nickel-titanium rotary instruments. J Endod; 35(11), 1469-1476.

Plotino, G, Grande, N. M, Cotti, E, Testarelli, L, & Gambarini, G (2014). Blue treatment enhances cyclic fatigue resistance of vortex nickel-titanium rotary files. J Endod, 40(9), 1451-1453.

Schäfer, E, Diez, C, Hoppe, W, & Tepel, J (2002). Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth. J Endod, 28(3), 211-6.

Silva, E. J. N. L., Vieira, V. T. L., Hecksher, F, Dos Santos Oliveira, M. R. S., Dos Santos Antunes, H, & Moreira E. J. L. (2018). Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clin Oral Investig, 22(7), 2633-2638.

Uygun, A. D, Unal, M, Falakaloglu, S, & Guven, Y (2020). Comparison of the cyclic fatigue resistance of hyflex EDM, vortex blue, protaper gold, and onecurve nickel-titanium instruments. Niger J Clin Pract, 23(1), 41-45.

Walia, H. M, & Brantley, W. A (1988). Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod, 14(7), 346-351.

Wei, X, Ling, J, Jiang, J, Huang, X, & Liu, L (2007). Modes of failure of ProTaper nickel-titanium rotary instruments after clinical use. J Endod, 33(3), 276-279.

Whipple, S. J, Kirkpatrick, T. C, & Rutledge, R. E (2009). Cyclic fatigue resistance of two variable-taper rotary file systems: ProTaper universal and V-Taper. J Endod, 35(4), 555-558.

Yared, G (2004). In vitro study of the torsional properties of new and used ProFile nickel titanium rotary files. J Endod, 30(6), 410-2.

Zelada, G, Varela, P, Martín, B, Bahíllo, J. G, Magán, F, & Ahn, S (2002). The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments. J Endod, 28(7), 540-542.

Zupanc, J, Vahdat-Pajouh, N, & Schäfer, E (2018). New thermomechanically treated NiTi alloys - a review. Int Endod J, 51(10), 1088-1103.

Downloads

Published

04/05/2022

How to Cite

RESENDE, L. C. .; MAIA , C. A.; SANTOS, A. M. C.; CAMPOS , G. O. .; SOARES JUNIOR , P. R. R.; FERNANDES , A. M. . Fatigue strength of Bassi LogicTM and Hyflex EDM endodontic instruments in an artificial canal with an extreme curvature. Research, Society and Development, [S. l.], v. 11, n. 6, p. e47511629570, 2022. DOI: 10.33448/rsd-v11i6.29570. Disponível em: https://www.rsdjournal.org/index.php/rsd/article/view/29570. Acesso em: 20 apr. 2024.

Issue

Section

Health Sciences