Alternative impression technique for edentulous anterior maxillary flabby tissue

Authors

DOI:

https://doi.org/10.33448/rsd-v9i10.8621

Keywords:

Flabby tissue; Impression technique; Soft tissue displacement.

Abstract

This present study describes an impression technique to rehabilitate patients with flabby ridge in pre-maxilla through complete dentures. The proposed technique consists on the association of nondisplacive impression of the flabby area in the primary and functional impression. Therefore, a primary impression was performed with irreversible hydrocolloid with a dual impression. The impression material was removed at the region corresponding to the flabby area, characterizing a window, where a re-impression was conducted with the same material in a more fluid consistency. The functional impression was executed with a custom tray with perforations at the flabby area fabricated over a primary anatomic cast previously relieved. As a result, an anatomic impression with reduced compression over the flabby ridge was obtained. Moreover, an accentuated decrease of the mucosa compression was obtained through the material overflow from the custom tray perforations at the functional impression. After the acrylization of the prosthetic piece, a delimited box corresponding to the flabby mucosa in the prosthesis base was verified. Thus, it is concluded that the association of techniques proposed in this study reduced the compression over the flabby ridge area resulting in a complete denture copying anatomically the flabby area at rest. Thereby, in this case through a precise negative reproduction, a more favorable retention of the maxillary complete denture was obtained in patients with flabby ridge at the pre-maxillary area. 

References

Ahmed A. (2017). Unconventional complete denture: Flabby ridge management: Case series. Int J Advanced Sci Res, 2(5), 50-51. Retrieved from http://allscientificjournal.com/.

Bansal, R., Kumar, M., Garg, R., Saini, R. & Kaushala, S. (2014). Prosthodontic rehabilitation of patient with flabby ridges with different impression techniques. Indian J Dent, 5(2), 110-113. doi:10.4103/0975-962X.135296.

Chakarvarty, K., Tomar, S. S., Tandam, P. & Modi, R. (2015). Managing flabby with different impression techniques:a case series. Int J Oral Care Res, 3(2), 95-99. Retrieved from http://www.ijocrweb.com/.

Gomaa, A. & El Mekawy, N. (2017). Impact of various impression techniques on maxillary flabby ridge tissue displacement (within-subject evaluation). Egyptian Dent J, 63(3), 1161-1169. Retrieved from https://edj.journals.ekb.eg/.

Jain, A. R. & Dhanraj, M. (2016). A clinical review of spacer design for conventional complete denture. Biol Med (Aligarh), 8(5):1-5.

Kazmi, S. M. R., Quraeshi, S. & Iqbal Z. (2013). Window’s impression technique for anterior fibrous maxillary ridges. J Dow Uni Health Sci, 7(2), 76-79.

Komiyama, O., Saeki, H., Kawara, M., Kobayashi, K. & Otake, S. (2004). Effects of relief space and escape holes on pressure characteristics of maxillary edentulous impressions. J Prosthet Dent, 91(6), 570-6. doi:10.1016/j.prosdent.2004.03.020.

Kulkarni, P., Kulkarni, R. S., Shah, R. J. & Tomar, B. (2018). Mishmash impression technique for managing maxillary anterior fibrous ridge. J Dent Mater Tech, 7(2), 63-68.

Labban N. (2018). Management of the flabby ridge using a modified window technique and polyvinylsiloxane impression material. Saudi Dent J, 30, 89-93.

Muthukumar, B., Deepak, K. & Ahila, S. C. (2012). Modified impression technique for a flabby maxilla – A clinical report. Univ J Dent Sci, 3(1), 71-74. Retrieved from http://www.srmjrds.in/.

Lynch, C. D. & Allen, P. F. (2006). Management of the flabby ridge: using contemporary materials to solve an old problem. Br Dent J, 200(5), 258-261. doi:10.1038/sj.bdj.4813306.

Pai, U. Y., Reddy, V. S. & Hosi, R. N. (2014). A single step impression technique of flabby ridges using monophase polyvinylsiloxane material: a case report. Case Rep Dent., 2014:104541. doi:10.1155/2014/104541.

Pereira, A. S., Shitsuka, D. M., Parreira, F. J. & Shitsuka, R. (2018). Metodologia da pesquisa científica. [e-book]. Santa Maria, Brasil: UAB/NTE/UFSM. Retrieved from https://repositorio.ufsm.br/bitstream/handle/1/15824/Lic_Computacao_Metodologia-Pesquisa-Cientifica.pdf?sequence=1.

Rawat, M. & Chadda, A. S. (2018). Management of flabby ridges using window technique and polyvinylsiloxane impression material in complete denture: a case report. Indian J Applied Res, 8(3), 8-9.

Shum, M. H. C. & Pow, E. H. N. (2014). Management of excessive movable tissue: a modified impression technique. J Prosthet Dent, 112(2), 387-389. doi:10.1016/j.prosdent.2013.10.018.

Singh, D. K., Dable, R., Tandon, P. & Jain, A. (2014). Prosthodontics rehabilitation a maxillary fibrous ridge – a case report. TMU J Dent, 4(1), 164-167.

Downloads

Published

28/09/2020

How to Cite

VERÍSSIMO, A. H.; RIBEIRO, A. K. C. .; CARDOSO, R. G.; MELO, L. A. de .; CARREIRO, A. da F. P. . Alternative impression technique for edentulous anterior maxillary flabby tissue. Research, Society and Development, [S. l.], v. 9, n. 10, p. e3269108621, 2020. DOI: 10.33448/rsd-v9i10.8621. Disponível em: https://www.rsdjournal.org/index.php/rsd/article/view/8621. Acesso em: 25 apr. 2024.

Issue

Section

Health Sciences